Share Categories Channel
1/5
2 to 22 Wheel Bus Truck RS232 TPMS Internal or External, RS232 TPMS, RS232 Truck TPMS image 1

2 to 22 Wheel Bus Truck RS232 TPMS Internal or External, RS232 TPMS, RS232 Truck TPMS

Dongguan Jiuan Electronic Technology Co., Ltd.

Price $135.00 / Sets
Mini Order
-+Subtotal: $1350
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

Model NO.
RS04T-6
Testing Equipment Type
Wireless
Certification
CE, ISO, RoHS
Update Method
by Email
Condition
New
Standard
Standard
Sensor Chip
NXP
Sensor Type
Internal or External
Screen Size
Haven′t Screen
Support Tire Number
up 22
Function
Tire Pressure and Temperature Measurement
Protocol
RS232
Working Voltage
DC9V to DC36V for Monitor and Repeater
Frequency
434MHz&Lf
Pressure Range
0 to 1400kpa
Working Temperature
-40ºC to 125 ºC
Battery Life Span
200kkm for Internal Sensor
Battery Model
Cr2450 Fro Internal Sensor
External Sensor Battery Life Span
<2years
External Sensor Battery Model
Cr1632 or Cr2050
Trademark
Jiuan
Transport Package
Box
Specification
1.5kg
Origin
China
HS Code
90262090
2 to 22 wheel bus truck rs232 tpms internal or external


Product introduction

      The system include sensors, repeater and receiver. It is used to monitor the pressure and temperature data of the tires. After collecting the pressure and temperature data, the sensors send the data to the repeater and receiver by wireless RF, then the repeater send the data to the receiver. The receiver send the data to RS232 network, The instrument or other display device collect all tire data and display from can network. When the pressure or temperature over or under warning valve value, the instrument will warn automatically to remind the users pay attention to the tires' situation.

1.3  System drawings

2,Applications

Applicable to the  tire pressure under 14Bar/203PSI

3,Product function features

3.1 Receiver(model:RS03T)

1Support rs232 and uart port
      2.Support 1 to 22 tires
      3.With the functions of ID learning/ID query/pressure and temperature measurement
      4. send the tires data to instrument or other display device by can-bus

3.2 Bandage sensors(model:T04)

  1. FSK modulating for RF signal, ASK modulating for LF signal
  2. All imports car-standard material, long life, high stability and strong anti-interference ability
  3. Air pressure and temperature can be measured and monitored simultaneously, and have self-test and tire leakage monitoring function
  4. Bandage sensor is only apply to all vacuum tire, external sensor is apply to all tire
  5. Adopt IP67 protection grade, but the external sensor is IP69
  6. Light weight, small volume

3.3 External sensor(Model:T02W AND T04W)

1,FSK modulating for RF signal, ASK modulating for LF signal
2,All imports car-standard material, long life, high stability and strong anti-interference ability
3,Air pressure and temperature can be measured and monitored simultaneously, and have self-test and tire leakage monitoring function
4,External sensor is apply to all tire
5,Adopt IP69 protection grade
6,Light weight, small volume
3.4 Repeater(Model:RP04)
  1. Transfer data, intelligent pull
  2. Support trailer exchange function
  3. When far distance and weak signal, can increase the signal strength to make sure the transferred signal reception reliability
  4. Full thread fixing type, adopt IPX6 anti-water testing standard
  5. Interior integration RF emit and receive function, high sensitive data receiving
  6. Trailer sensors and receiver data transmission
  7. Sole corresponding ID code, prevent data collision
4. Product technical parameter

4.1 Receiver

No.ItemTechnical parameter
1Input voltageDC 5V to DC12
2Working current<=10mA
4HF receive frequency433.92MHz±50KHz
5HF receive sensitivity<-105dBm
6Working temperature range-40ºC~85ºC
7Data transmission modeSerial port
8Baud rate for RF signal19200bps
9RF codingManchester

4.2 Bandage sensor

No.ItemTechnical parameter
1Battery model No.CR2450(550 mAh)
 2RF frequency433.92 MHz±38 KHz
3Standby current<0.7 uA
4Emission current<8 mA
5HF emission power<8 dbm(50Ω)
6HF modulation modeFSK
7LF receive frequency125 KHz±5 KHz
8LF modulation modeASK
9Pressure measurement range0-1400kpa(0~203PSI)
10Pressure resolution2.75 KPa/0.39psi
11Pressure measurement accuracy±10kpa/±2.9psi(0ºC~70ºC)
±48kpa/±6.96psi(-40ºC~125ºC)
12Temperature measurement range-40ºC~125ºC
13Temperature resolution1ºC
14Temperature measurement accuracy±3ºC(0ºC~70ºC)
15Working temperature range-40ºC~125ºC
16Storage temperature range-40ºC~125ºC(Suggest storage in normal temperature)
17Protection gradeIP67
18Battery lifespanOver 5 years
 

4.3 External sensor(T02W)

     No.ItemTechnical parameter
1Battery model No.CR1632(180mAh)
 2RF frequency433.92 MHz±38 KHz
3Standby current<0.7 uA
4Emission current<8 mA
5HF emission power<8 dbm(50Ω)
6HF modulation modeFSK
7LF receive frequency125 KHz±5 KHz
8LF modulation modeASK
9Pressure measurement range0-1400kpa(0~203PSI)
10Pressure measurement accuracy±10kpa/±1.45psi(20ºC~50ºC)
±48kpa/±6.96psi(-40ºC~125ºC)
11Temperature measurement range-40ºC~125ºC
12Temperature measurement accuracy±4ºC(0ºC~70ºC)
13Working temperature range-30ºC~85ºC
14Storage temperature range-20ºC~85ºC(Suggest storage in normal temperature)
15Protection gradeIP69
16Battery lifespanOver 2 years(Battery can be replace)

4.4 External sensor(t04w)

     No.ItemTechnical parameter
1Battery model No.CR2050(480mAh)
 2RF frequency433.92 MHz±38 KHz
3Standby current<0.7 uA
4Emission current<8 mA
5HF emission power<8 dbm(50Ω)
6HF modulation modeFSK
7LF receive frequency125 KHz±5 KHz
8LF modulation modeASK
9Pressure measurement range0-1400kpa(0~203PSI)
10Pressure measurement accuracy±10kpa/±1.45psi(20ºC~50ºC)
±48kpa/±6.96psi(-40ºC~125ºC)
11Temperature measurement range-40ºC~125ºC
12Temperature measurement accuracy±4ºC(0ºC~70ºC)
13Working temperature range-40ºC~125ºC
14Storage temperature range-20ºC~65ºC(Suggest storage in normal temperature)
15Protection gradeIP69
16Battery lifespanOver 5 years(Battery cann't be replace)

4.5 repeater

No.ItemTechnical parameter
1Working voltageDC 9 V ~ 30 V
2RF signal emit center frequency433.92 MHz
3RF emit signal modulation modeFSK
4RF emit signal coding schemeDBP Manchester
5RF emit signal baud rate5K bps
6RF signal emit power< 10 dbm
7RF signal receive sensitivity-105 dbm
8Maximum working current< 150 mA
9RF signal receive center frequency433.92 MHz
10Working temperature-40ºC ~ 85ºC

Send Message