Share Categories Channel

1/6
Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle image 1Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle image 2Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle image 3Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle image 4Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle image 5Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle image 6

Dr X-ray Lung Detection Vehicle, Lung Detection Vehicle, Mobile Dr Medical Examination Vehicle

Chengli Special Automobile Co., Ltd.

Price $82800.00 / SET
Mini Order
-+Subtotal: $82800
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

Model NO.
CLW5049XYL
HS Code
870190119
Production Capacity
50 Set/Month
Type:
B
Warranty:
1 Year
Transport Package:
by RO-RO Ship
Specification:
5940*2110*2750
Trademark:
CLW
Origin:
China

SAIC MAXUS V90DR medical examination vehicle
Detailed Photos
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle

 

Dr X-ray Lung Detection Vehicle
Register at the middle door and enter the DR inspection cabin. The cabin door automatically closes and the red light comes on. 

 

Dr X-ray Lung Detection Vehicle
After the detection is completed, the red light goes out and the passenger disembarks from the tailgate.
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle
Dr X-ray Lung Detection Vehicle

 

Product Parameters
Product Name
Mobile Animal Hospital
Key word
Caravan
Overall dimension
5940×2110×2750mm
Total Mass
4495kgs
Wheelbase
3760mm
Curb weight
4100kgs
F/R hanging1020/1160
F/R Axle load
1750/2745
Engine
SC20M150Q6
Power
110(kw)/149.6(ps)
Equipment :DR medical examination equipment
 
ON.Configuration NameDr Production Construction Orderunitquantity
Cabinet body
1carriage assemblyBody skeleton, lightweight body skin, and insulation materialsset1
2Double tailgateWith door lock mechanismset1
3carrosserie appearanceCustomized according to customer requirementsset1
4Office cabinetLeft office console, customizable according to customer sizeset1
Electrical system
1Inverter electrical systemWith charging function, pure sine wave 1000Wset1
2External power supply systemHigh power docking socketset1
3Indoor lightingLED form, 12Vset2
4Exterior lightingLED form, 12Vset1
5Car air conditioningCooling capacity 3000, heating capacity 3000set1
6Central control systemIndependent power supply central control system, safe and convenientset1
7monitoring systemIndependent recording of each work area  
8Navigation integrated machineReverse imageset1
9Courtesy lights1 work indicator light, displaying a reminder along with the door switchset1
10Power distribution system30 meter external wire on the reelset1
Interior seat system
1Cabin interiorPolymer material, antibacterial, anti-corrosion, and easy to cleanset1
2Medical flooringOverall plastic, waterproof, anti-corrosion, wear-resistant, mold resistant, environmentally friendly, fireproof (including bottom lead plate)set1
3seatLifting small rotating seatset1
Lead room
1lead sheath4mm thick lead plate is selected for protection (that is, the upper, lower, and surrounding areas of the machine room are protected with lead. The lead plates on the front and back of the ball tube are 4mm thick, the lead plates on the side are 4mm thick, and the lead plates on the top and bottom are 2mm thick)set1
2lead  door2 sets of electric sliding doors  
3Lead door observation windowThe vehicle mounted X-ray machine is installed in a channel style, with lead glass with good radiation resistance embedded on the electric lead door at the entrance and exit of the subject: 400 × six hundred × 20 mm (length × wide × Thick) 1 piece (customizable)  
4Lead room indoor lightingLED Form,12Vset2
5Lead room disinfection lampUV disinfection lampset1
6Dirt bucketBiohazard Wastesset1
7fire extinguisherDry powder type, equipped with 1 kg dry powder fire extinguisher in the detection cabinset1
Car Stability System
1111Support deviceEquipped with two manual balancing legs, used to stabilize the body balance during parking examination, without affecting the quality of the film due to the shaking inside the car caused by the examination personnel moving up and down.set1
DR installation
1DR installationInstall different brands with reasonable size and locationset1

DXR-530(B)Technical parameters of on-board
ON.Technical parameters
1System Overview
1.1Equipment use: Installed on a medical examination vehicle to complete mobile full digital X-ray photography examination;
2body frame
2.1Vehicle specific column frame: The bracket is fixed and installed on the vehicle
2.2Car rack: The range of movement between the chest film rack and the ball tube column: 450mm;
2.3Ball tube and flat panel detectors can be synchronized and automatically tracked;
2.4SID:1.8m;
3X-ray tube assembly
3.1Nominal tube voltage: 150KV;
3.2The anode is a rotating anode with a thermal capacity of 300kHU;
3.3Nominal value of focus: small focus: 0.6mm, large focus: 1.2mm;
3.4Nominal anode input power: large focus: 50kW, small focus: 20kW;
3.5Anode target angle: 12 degrees
3.6Anode speed: 3200rpm
3.7Inherent filtration: 1.2mmAl/75kV
3.8Heat capacity of tube components: 1250KHU
4High voltage generator assembly
4.1Input power supply; 220v±10%
4.2Nominal output power: 50kW;
4.3Output voltage range: 40-150kV ;
4.4Output current range: 10~630mA;
4.5Current time product range: 0.5mAs~630mAs;
4.6Loading time: 0.001s-6.3s;
4.7Inverter frequency: 400KHz
5Flat panel detector assembly
5.1Imaging material: amorphous silicon;
5.2Scintillator type: cesium iodide;
5.3Pixel matrix: 3072 × 3072pixels
5.4Effective image range: 430mm × 430mm;
5.5Pixel size: 139um
5.6Conventional spatial resolution: 3.7LP/mm
5.7A/D output: 16 bits;
5.8Filter grid specification: size: 457X457mm, grid density: 40L/cm
5.9No residual shadows, no artifacts;
6Beamer HMC-38
6.1Inherent filtration: 1.2mmAl/75KVp
6.2The size of the irradiation field can be automatically set according to the examination type;
7Integrated graphic acquisition and processing workstation
7.1Windows operating system;
7.3CPU:i5-4590/3.3GHz
7.4Memory capacity: 8GB
7.5Hard disk capacity: 1T
7.6Interface: Standard DICOM
7.7Image display: 19 inch display
7.8information management
a) Patient input function;
b) Photography inspection function;
c) Image browsing function;
d) Data management and transmission functions;
e) Image transmission in DICOM format through the network;
f) Diagnostic report printing function;
g) Position diagram ≥ 128;
Maximum programmable APR: 2000;
7.9Support scanning gun scanning registration.
7.10Support scanning gun scanning registration. ID card and social security card readers (supporting large-scale table import of patient information)
7.11Support mass export of patient films.
7.12Automatically save patient videos and archive them according to the date folder.
DXR-530 digital medical radiography system (model B)
  Configuration List
ON.Component Namemodelquantityunit
1Flat panel detectorHMD-1717X1set
2X-ray tube assemblyHMT-171set
3High voltage generatorHMG-541set
4body frameHM-OBD1set
5BeamformerHMC-381set
6Filter gridJPI/GRID-1000 1set
7High voltage cableWBX-Z75kV-T1set
8Call intercom systemSD-2016V1set
9Image acquisition workstationHMS-0031set
10Qixi Medical Digital X-ray Capture Software V1.0V1.01set
11ID card reader/1set
12Scanning gun/1set
13Social Security Card Reader 1set
Company Profile

Dr X-ray Lung Detection Vehicle

 

Dr X-ray Lung Detection Vehicle

 

Dr X-ray Lung Detection Vehicle

 

Dr X-ray Lung Detection Vehicle

 

Dr X-ray Lung Detection Vehicle
 
Dr X-ray Lung Detection Vehicle
 
 

Send Message

Content*

Your Name

Tel*

Email*