MICA-500W
Lithium-Ion Batteries
Car, Electric Power, Lighting, Boat, Camping/Emergency Use
High Discharge Rate
Square Battery
Li-ion
Packaged
Chargeable
5 Years
135000mAh
500W
MICA/OEM
Color Box
280*200*200mm
China
Product Description
No | Items | Parameter | Standard |
1 | Model | MC500 | |
2 | Battery type | Li-ion 18650 cell | 3.7V |
3 | Rated Capacity | 135000mAh | |
4 | Output | USB output port | 3*QC 3.0 USB(5V/3A ) |
USB output port working time | >30h | ||
DC output port | 14V4A/14V8A | ||
DC output port working time | >8h | ||
AC output port | 110V/500W Pure Sine Wave | ||
Type-C | 5V/3A | ||
Car output port working time | >2.5h | ||
cigarette lighter | 14V/8A | ||
Wireless Charging | 10W | ||
LED | 3W | ||
Reverse charging protection | Yes | ||
5 | Charging | Charging voltage | 12-28V |
Charging Current | 10A | ||
Charging Time | About 10h | ||
6 | Self-consumption | On working | 200mA |
On standby | 5mA | ||
7 | Dimensions | L*W*H | 280*200*200mm |
8 | Weight | Weight(Net weight) | 4.8kg |
Weight(with accessories) | 5.8kg | ||
9 | Range of Working Temperature | Charging | 10ºC~40ºC |
Discharging | 0ºC~75ºC | ||
10 | Range of Storage Temperature | Less than 1 year | -20ºC~+25ºC |
Less than 3 months | -20ºC~+45ºC | ||
Less than 1 month | -20ºC~+60ºC |
Package including:
No | Name | Model | Unit | Quantity |
1 | Portable power station | MC500 | pcs | 1 |
2 | Adapter | 25V 4A | pcs | 1 |
3 | Solar charging wire | pcs | 1 | |
4 | Car charger line | pcs | 1 | |
5 | User manual | pcs | 1 |
Functional Description:
AC output:
(1)Press the AC output button;
(2)The AC output indicator shows blue and can be loaded. If the indicator is off and the buzzer sounds, the AC output is faulty.
DC output: connect the load to DC ports directly. When there is no load, the DC port is in the sleep state.Drone output: connect the drone port to the drone charger directly by pressing the positive and negative poles.
DC input: connect the charging adapter and AC socket to the charging port of the portable 8 Lithium Battery Expert 15 Years power station for charging, the battery indicator shows the power when charging; disconnect all loads when charging;
Performance Test:
1.Standard test conditions
The test product must be a new product that has not been shipped for more than one month and the battery has not been cycle charge and discharge more than 5 times. Unless otherwise specified, the tests in this specification shall be under the following
conditions:Temperature:23ºC±2ºC;
Relative humidity:45%~85%RH;Atmospheric pressure:86kPa~106kPa;
2.Measurement Apparatus
(1)Dimension Measuring Instrument
The dimension measuring shall be implemented by instruments with equal or more precision scale of 0.01mm;
(2)Voltmeter Standard class specified in the national standard or more sensitive class having inner 7 Lithium Battery Expert 15 Years impedance not less than 10kΩ /V
The dimension measuring shall be implemented by instruments with equal or more precision scale of 0.01mm;
(2)Voltmeter Standard class specified in the national standard or more sensitive class having inner 7 Lithium Battery Expert 15 Years impedance not less than 10kΩ /V
(3)Ammeter
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω\
(4)The resistance test method is the AC impedance method (AC 1kHz LCR)
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω\
(4)The resistance test method is the AC impedance method (AC 1kHz LCR)
The resistance is not a constant value and varies with temperature and saturation of the state of charge, and related to length and capacity of the cable.
(7)The temperature measuring instrument should not be lower than ±0.5°C;
(5)All testing equipment and measuring instruments must be inspected by the certification institutes;
(6)Battery test system current accuracy should be within ±0.1%, constant pressure accuracy within ±0.5%, timing accuracy within ±0.1%;(7)The temperature measuring instrument should not be lower than ±0.5°C;