BD-AV, AV2
Electromagnetic
Analog Output
Integration
Plastic
0.5G
PLC, Energy Meter
IP30
CE, RoHS
Customized
AC&DC, Voltage&Current
DC4-20mA, DC0-20mA, DC1-5V, DC0-5V
DC24V, DC48V, DC100V-350V, AC85V-265V
RS485, Modbus-RTU
Less Than 400ms
More Than 100mΩ
Acrel
Carton
China
9030339000
Product Description
BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current, voltage frequency, power, power factor or temperature, resistance, and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters also can be connected with automatic control devices (eg PLC), a variety of A / D converters, and the computer system.


Specifications | BD-AI BD-AV | BD-F | BD-PF | BD-3I3 BD-3(4)V3 | BD-3(4)P BD-3(4)Q | BD-3(4)E | ||
Phase&Wiring | 1P2W | YES | Optional | Optional | Optional | Optional | Optional | |
3P3W | / | / | Optional | Optional | Optional | Optional | ||
3P4W | / | / | Optional | Optional | Optional | Optional | ||
Input | Voltage | Direct L-L | Up to 480V AC | |||||
Direct L-N | Up to 276V AC | |||||||
With external PT | YES | YES | YES | YES | YES | YES | ||
Current | Direct | Up to 5A AC | ||||||
With external CT | YES | YES | YES | YES | YES | YES | ||
Measuring | Voltage | Optional | / | / | Optional | |||
Current | / | / | Optional | Optional | Optional | |||
Active/Reactive Power | / | / | / | / | Optional | Optional | ||
Apparent Power | / | / | / | / | Optional | Optional | ||
Power Factor | / | / | / | Optional | Optional | |||
Frequency | / | / | / | Optional | Optional | |||
Energy Metering | ±KWh | / | / | / | / | / | Optional | |
Accuracy Class | 0.50% | |||||||
communication | Interface:RS485 Protocol:Modbus-RTU | Optional | Optional | / | Optional | Optional | Optional | |
Analog Output | DC 0-5V,0-10,0-20mA,4-20mA | |||||||
Pulse Output | / | / | / | / | / | YES | ||
Dimensions(mm) | Housing(W×H×D) | 138×76×24 | 119×75×55 | 119×75×55 | 112×110×75 | 112×110×75 | 112×110×75 | |
Auxiliary Power | AC/DC 85-265V,DC 24V,DC48V | |||||||
Temperature | Operation | -10 to +55ºC | ||||||
Storage | -25 to +70ºC | |||||||
Humidity | Up to 95%,no condensing | |||||||
Installation | (Rail)DIN35, fix on cubicle with screws | |||||||
Standards | GB/T 13850 |
Type | BD-DI BD-DV | BD-AI BD-AV | BD-3I3 BD-3V3 BD-4V3 | BD-3P BD-3Q BD-3P/Q/I | BD-4P BD-4Q BD-4P/Q/I | BD-3E BD-4E BD-4EA | BD-PF BD-F | |
Class | 0.5 | |||||||
Input | Signal | DC 4-20mA | AC 0-1A | AC 1A | ||||
DC 0-20mA | AC 0-5A | AC 5A | ||||||
DC 0-10V | AC 0-120V | AC 100V | ||||||
DC 0-75mA | AC 0-300V | AC 220V | ||||||
DC 0-300V | AC 0-500V | AC 380V | ||||||
Overload | Current:1.2 times everiasting, 10 times/1s | |||||||
Voltage:1.2 times everiasting, 2 times/1s | ||||||||
Frequency | 45Hz-65Hz | |||||||
Output | Signal | DC 4-20mA,0-20mA,0-5V,0-10V | ||||||
Load | Current Output≤600Ω Voltage Output≥1000Ω | |||||||
Selected function | / | RS485 | / | RS485 communication | ||||
Power supply | AC 85V-265V/DC 100V-350V or DC24V or DC 48V | |||||||
Temperature drift coefficient | Class 0.5≤200ppm/ºC, class 0.2≤100ppm/ºC | |||||||
Response time | <400ms | |||||||
Insulation resistance | ≥100MΩ | |||||||
Power frequency withstand voltage | the value of alternating current between the power supply, input, and output:2kV/1min | |||||||
Environment | Temperature | operating temperature:-10 to +55ºC storage temperature: -25 to +70ºC | ||||||
Humidity | ≤95%RH, no dew, no aggressive gas | |||||||
Altitude | ≤2500m | |||||||
Installation method | TS35mm rail designed or screw |

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.