Specification | ||||
AC Nominal Input | Input Voltage | 260-530VAC ; 3-phase (without neutral supported) (Wide input voltage range,allows operation in most poor grid conditions) | ||
Frequency | 45Hz-65Hz (Suitable for both EU and US market) | |||
DC Nominal Output | Output Efficiency | >94% (Rated input and output) | ||
Output Parameter | 30KW 150V-550VDC 70A (15KW /20KW / 40KW option; 750V DC / 1000V DC option) | |||
Electrical Specification | HMI | Colorful 7" Touch screen+LED Indicato+Emergency Stop Button | ||
Start / Stop Method | RFID Card; QR Code | |||
Energy Meter | Certificated DC energy meter | |||
Structure Design | Housing Material | Metal case | ||
Application scenes | Commercial / Public Use (Both indoor & Outdoor Installation) | |||
Charging Standards | Combo CCS1 / Combo CCS2 / CHAdeMo option | |||
Charging Outlet Quantity | 1 or 2 | |||
Cable Length | 4M cable | |||
Communication | Network Method | Ethernet; 3G/4G / Wifi for Option | ||
Communication Protocol | CAN, PLC (DIN70121 and ISO15118) | |||
OCPP 1.6 JASON ( Charger with ocpp board inside) | ||||
Environmental Index | Operating Temperature | -20~+70°C, full output under 50°C, power derating 5%/° above 50°C | ||
Working Humidity | 5%~95% without condensation; <2000M | |||
Protection Grade | IP54 / IK10 | |||
Cooling Method | Fan cooling | |||
Security Protection | Multi le Protection | Over-current,Over/Under Volatge,Short Circuit Protection,Reverse Polarity,Over-temperature Protect Earth Connect Monitoring,RCD Protections | ||
MTBF | 100,000 hours | |||
Safety Standard | CE Certificated ( IEC 61851-1:2017; IEC 61851-23:2014; EN 61851-1:2019; EN 61851-23:2014; EN 61851-24:2014; EN 61851-21-2001 EMC) | |||
Warranty | 12 months | |||
Dimension | Dimension & Weight | 610*650*313 mm & 50KG (weight without charging module) | ||
Optional Parts | Floor-stand Pile | Floor-stand Pile | ||
Cstomized | Customized Service | Brand / Color / Language etc... |



Send Message