Share Categories Channel
1/6
O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor image 1O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor image 2O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor image 3O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor image 4O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor image 5O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor image 6

O2 Oxygen Sensor Scuba Diving Sensor 0-100 Vol% O2/D-13, Oxygen Sensor, O2 Sensor

Advanced Sensors Application Technology Co., Ltd.

Price $200.00 / Pieces
Mini Order
-+Subtotal: $600
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

Model NO.
O2/D-13
Type
Electrochemical Gas Sensor
Conductivity Type
Volume Control Type
Output Signal Type
Digital Type
Production Process
Integration
Material
PA, PPS, PTFE, Stainless Steel
IP Rating
IP20
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
Ttl/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
ITG
Transport Package
Factory Sealed
Specification
Max29.2*41.4
Origin
Germany
HS Code
9027100090
ITG O2 - Industrial Sensor / Type D-13
Galvanic gas sensor with an extra water repellent head space.
All characteristics are based on conditions at 25°C, 50% RH and 1013 hPa

 
Key Feature
Measurement Range0 to 100 Vol.%
Expected Operating Life~ 750,000 Vol.% h
Sensor Lifetime<3 years @ ambient air
Electrical Connector3-pin Molex®
Initial Output Signal7.0-13.5 mV @ dry ambient air
Response Time t90<5 s
Drift<1% volume O2/month @ air, averaged across 12 months
Operating Temperature0 to 45ºC
Pressure Range600 to 1750 hPa
Recommended Load Resistor≥ 10 kOhm
Linearity Error<3 % @ 100 % O2, applied for 5 min
Zero Offset Voltage< 150 μV in 100% N2, applied for 5 min
Influence of Humidity- 0.03 % rel. O2 reading per % RH
Temperature CompensationNTC
Interferencesnone to He, H2 and CO
Weightapproximately 24 g
Material in Contact with MediaPA, PPS, PTFE, stainless steel

Storage Condition
Temperature Rangerecommended:  5 to 30 °C
maximum:  -20 to 50 °C
Humidityup to 100 % RH
Shelf Life< 6 months recommended
Ambient Pressure600 to 1750 hPa


Oxygen Module Parameters
Module typeGM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gasToxic gas
Detecting principleElectrochemistry
SamplingDiffusing  pump  flange  thread
Responding time30s~40s(of the sensor)
Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability≤±2% FS
Module linear error≤±2% FS
Module zero temperature drift≤±2% (FS/year)
Module operating temperature-40~80°C
Module humidity0-95%RH(non-condensation)
Sensor operating temperature-20°C~50°C
Sensor humidity0-90%RH(non-condensation)
Signal outputTTL/4-20mA /RS485   (two or three wire)
Transmitting distance1000 meters(RS485)
Operating voltageDC 12-36V
Maximum power≤0.8W
Size80*48mm
Explosion proofIntrinsic safe
Connection cableRVVP3 x 1.5mm²

Oxygen Module Applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control