Model NO.
Veinasa-CO2-2
Accuracy
±(50ppm+5% *Reading)
Range
400~5000 Pm
Operating Temperature Range
-10~+50ºC
Operating Humidity Range
0~85% No Condensation
Storage Temperature Range
-40~+75ºC
Mean Time Between Failures
10 Year
Rresponse Time T90
120s
Transport Package
Covered with Carton Packing
Trademark
VEINASA
Origin
China
Customized:
Customized
Product Name:
Carbon Dioxide Sensor
Application:
Carbon Dioxide Sensor CO2 Gas Detector Collector
Veinasa-CO2-O2 temperature humidity carbon dioxide air quality detector co2 monitor indoor co2 sensor air quality monitoring

C8 is a mini infrared carbon dioxide sensor module that uses NDIR gas sensor technology to measure the
concentration of carbon dioxide in indoor air. It has small design, excellent performance and easy installation. It can be widely
used in air purifier, fresh air system, air conditioner with purification function, air quality detection instrument, agricultural
Internet of things, automobile and consumer electronics.

and determine the gas concentration through the relationship between gas concentration and absorption intensity (Lambert Beer law)
according to the absorption characteristics of different gas molecules for near-infrared spectrum. CO2, CO and other molecules
composed of heterogeneous atoms have absorption spectra in the infrared wavelength region, and their absorption intensity follows
Lambert Beer law. When the light wave corresponding to the characteristic absorption wavelength of a gas passes through the
measured gas, its intensity will be significantly weakened. The degree of intensity attenuation is related to the gas
concentration, and the relationship between them complies with Lambert Beer law. The basic principle and structure of NDIR sensor
are shown in the figure below

Parameters | Index | nit |
Range | 400~5000 | pm |
Resolution | 1 | pm |
Accuracy | ±(50ppm+5% *reading) | |
Response Time T90 | <120 | S |
Data update time | <3(standard 1s) | S |
Preheating time | <25s(operable) <2min(90% accuracy) <10min(maximum accuracy) | |
DC power supply | Typ:5.0 Min:4.5 Max: 5.5 | V |
Working current | peak value80, average30 | mA |
Data interface level | L <0.8 @3.3 H >[email protected] | V |
Operating temperature range | -10~+50 | ºC |
Operating humidity range | 0~85% No condensation | |
Storage temperature range | -40~+75 | ºC |
Mean time between failures | 10 | Y |
Maximum size* | 33×21×11 | MM |
Pin Pitch | 2.54 | MM |






Send Message