Model NO.
RK-3001-CO2_LoRaWAN
Type
Electrochemical Gas Sensor
Output Signal Type
Analog Type
Material
Metal
IP Rating
IP68
Sensitivity
High
Certification
CE RoHS FCC
Customized
Customized
Product Name
Lorawan CO2 Transmitter Three-in-One Sensor
Trademark
Rainbow
Transport Package
Standard
Origin
China
Carbon Dioxide Temperature and Humidity Three-in-One Sensor
RK-3001-CO2_LoRaWAN
Chapter 1 Product Introduction
1.1 Product overview
Our self-developed LoRaWAN carbon dioxide three-in-one device has the characteristics of small size and integration. It is convenient to transport, carry and install, and can be adjusted dynamically at any time. The appearance of the equipment,working conditions, safety requirements, functional requirements and communication requirements can all be adapted to different measurement environments.
The device measures data in real time and uses wireless networks for transmission. The product network transmission adopts a stable and reliable operator network with mature technology, stable transmission, strong signal and wide coverage. At the same time, the device supports timing data collection and active upload to the server platform.
1.2 LoRaWAN features
1.Transmission distance: up to 1km in towns, up to 3km in open suburbs;
2.Working frequency: ISM frequency band including 433, 868, 915 MHZ, etc.
3.Modulation method: based on spread spectrum technology, a variant of linear modulation spread spectrum (CSS), with forward error correction (FEC) capability, proprietary patented technology of semtech;
4.Transmission rate: hundreds to tens of Kbps, the lower the rate, the longer
4.Transmission rate: hundreds to tens of Kbps, the lower the rate, the longer
the transmission distance.
1.3 LoRaWAN product advantages
1.Low cost, wide coverage, low power consumption, long life.
2.Consistent, stable and reliable.
3.Long transmission distance, strong signal, flexibility in deployment services.
4.Battery life and long service life.
5.A physical layer modulation technology, which can be used in different protocols.
6.Good security and confidentiality.
1.4 Product parameters
1.4.1 Probe parameters
CO measurement range | 0-1000ppm |
measurement method | Electrochemical sensors |
CO accuracy | <±3% of reading (25ºC) |
Response time (T90, seconds) | Less than 30 seconds |
Long-term temperature stability | ≤0.1ºC/year |
Long-term humidity stability | ≤1%year |
temperature range | -40ºC-80ºC (can be customized) |
Humidity range | 0-100%RH |
Temperature resolution | 0.1ºC |
Humidity resolution | 0.1%RH |
1.4.2 Probe selection
The service life of the above probes is in an air environment with a temperature of 23±3ºC and a humidity of 40±10%RH.
1.4.3 LoRaWAN parameters
Chapter 2 Hardware Connection
2.1 Inspection before equipment installation
Please check the equipment list before installing the equipment:
Please check the equipment list before installing the equipment:
2.2 Product appearance
The following is the appearance size of the product, you can install the sensor reasonably according to the product size, as shown in the figure:
(1) Battery powered version
(2) Power supply version
(2) Power supply version
2.3 How to use
(1) In the first step, the LoRaWAN gateway uses a power adapter for power supply.
(2) In the second step, if the LoRaWAN node is powered by a battery, press the sensor power button; if the LoRaWAN node is powered by a power adapter, just send the power adapter delivered by our company to supply power.
(3) After the LoRaWAN gateway and the node are powered on, the node and the gateway establish a connection through the wireless network, and the sensor will report the collected data to the gateway according to a certain frequency.
(4) There are two ways to view data, one is in the LoRaWAN gateway; the other is that users can view data on their own private server or TTN server.
2.4 matters needing attention
(1) For the use of LoRaWAN gateway, please refer to the gateway manual.
(2) Use outdoors, and cannot be placed in a low-lying, confined environment.
(3) LoRaWAN gateway needs to be placed in a higher position to enhance signal reception.
(4) Moisture-proof and high-temperature treatment should be done for outdoor use.
Chapter 3 Data Protocol
3.1 Reporting data format
Analyze and explain with examples:
fa ad 08 00 00 01 17 00 00 01 20 00 00 28 bf
fa ad-fixed header 2 bytes
08-Data length 1 byte
00 00 01 17 and 00000120 are two data, each data is 4 bytes
00 00-error code 2 bytes
28bf-CRC check 2 bytes Standard CCITT-CRC16 check used